2. Normative References
The following documents contain provisions, which, through reference in this text, constitute provisions of the standard. At the time of Subcommittee approval, the editions indicated were valid. All standards are subject to revision; and while parties to any agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the documents listed below, they are reminded that newer editions of those documents may not he compatible with the referenced version.
2.1. SCTE References
• ANSI/SCTE 04 2014— Test Method for “F” Connector Return Loss
• ANSI/SCTE 48-1 2015 — Test Method for Measuring Shielding Effectiveness of Passive and Active Devices Using a GTEM Cell
• ANSL’SCTE 103 2012 — Test Method for DC Contact Resistance, Drop cable to F- Connectors and F81 Barrels
• ANSIJSCTE 144 2012 — Test Procedure for Measuring Transmission and Reflect ion
2.2. Standards from other Organizations
• Beilcore GR-1503-CORE 4.8
• 1EC60169-1
• EIA-364-65
• MIL-STD-202
3. Informative References
The following documents may provide valuable information to the reader hut are not required when complying with this standard.
3.1. Standards from other Organizations
• MIL-STD-889
7.3.1. Insertion and Retention Force Depending on whether the MMCX-75 interface connections are to be used individually or in conjunction with a multi-connector header, the required interface insertion and retention forces can vary. The data in this specification is for individual connector mating forces. Manufacturer specifications for the female socket insertion and retention forces should meet equipment requirements when tested as follows
7.3.1.1. Gauge A Gauge A is to be inserted and removed from the female connector socket 5 times. Both insertion force and retention force are to be measured during the fifth insertion and removal.
7.3.1.2. After testing After testing is complete using Gauge A, then Gauge B is to be inserted and removed from the female connector socket while measuring insertion and retention force. For an individual MMCX-75 Female socket the maximum insertion force should not exceed 10 N and the retention force should not exceed 10 N using Gauge A. The minimum insertion force should not be less than .25N and the retention force should not be less than .25N using Gauge B.
7.4.1. Insertion and Retention Force Depending on whether the MMCX-75 interface connections are to be used individually or in conjunction with a multi-connector header, the required interface insertion and retention forces can vary. The data in this specification is for individual connector mating forces. Manufacturer specifications for the male plug insertion and retention forces should meet equipment requirements when tested as follows 7.4.1.1. Gauge A Gauge A is to be inserted and removed from the male connector plug 5 times. Both insertion force and retention force are to be measured during the fifth insertion and removal. 7.4.1.2. After Testing After testing is complete using Gauge A, then Gauge B is to be inserted and removed from the male connector plug while measuring insertion and retention force. For an individual MMCX-75 Male Plug connector the maximum insertion force should not exceed 63 N and the retention force should not exceed 20 N using Gauge A. The minimum insertion force should not be less than 4.9Nand the retention force should not be less than 4.9 Nusing Gauge B.